1 TODO summary table– setups

Yang et al. \cite{} did a classic experimental study on viv of a rigid cylinder near a rigid plane boundary.

Barbosa (2017) extended yang's work by including more gap ratios (0-5) and enhancing the wake osciliater model incorporating plane bounary effects.

8.3.2 sumer, 1997

Authors, year, source methods flow regime Re (GP) G/D (GP) m* ζ m*ζ (GP) waves (kc) Current BL(GP) DOF Ur(GP) New keynote independent variables dependent variables
Chern, 2018,JoM Num. laminar 100 0.35,0.6,0.8,1.5 10 0 0 - steady   2   Num. 2D, 2DOF effect of viv on plane boudnary(skin friction) X, Y,Cf, fv/fn, trajectory 1
Chung, 2016 Num. laminar 100   2 0 0 - steady   1   examine G/D effects only, excluding effects of the BL by moving the plane boundary G/D ↑, A* ↓, lock-in region ↑,Urmax    
Munir, 2018, OE Num., 2D,RANS subcritical 5k 0.01, 0.4, 1.0 ∞ 2 0 2*0 pure cosine wave:5,10, -   2 1-15 cosine wave at inlet      
Barbosa, 2017, JFS Exp. subcritical 6500-20,000   5.5 - - - steady              
Yang, 2009, Acta Mech Sin Exp. subcritical 2600-15,574 0.06-1.69 1.36,2.6 0.0152   - steady   1 2-12 early Exp. study on viv near plane      
Hsieh, 2016,JFS Exp. subcritical 3036~3924 0.8 5.67 0.0106 .601 - steady   1 5.39-6.96 high resolution PIV, Accurate measurements at the viscous sublayer      
Sumer 1994 Exp. subcritical 60,000               1          
wang, 2013, JFS Exp. subcritical, 3k-13k 0.05-2.5 1 0.0173 0.0173 - steady - 1 1.53-6.62        
  • ν of water: 1.002e-6
  • GP: govening/influencing parameters
  • flow regime is based on table 1-1, zdravkovich, 1997
  • DOF : degree of freedom

ref: table 1-1, zdravkovich, 1997

table 10.1 sumer,1997{B}

  • where, B means book

Footnotes:

1

DEFINITION NOT FOUND.

Author: ka

Created: 2019-10-16 三 12:55

Emacs 25.2.2 (Org mode 8.2.10)

Validate

标签:GP,wall,steady,near,plane,VIV,Exp,table,subcritical
来源: https://www.cnblogs.com/code-saturne/p/11684866.html

本站声明: 1. iCode9 技术分享网(下文简称本站)提供的所有内容,仅供技术学习、探讨和分享;
2. 关于本站的所有留言、评论、转载及引用,纯属内容发起人的个人观点,与本站观点和立场无关;
3. 关于本站的所有言论和文字,纯属内容发起人的个人观点,与本站观点和立场无关;
4. 本站文章均是网友提供,不完全保证技术分享内容的完整性、准确性、时效性、风险性和版权归属;如您发现该文章侵犯了您的权益,可联系我们第一时间进行删除;
5. 本站为非盈利性的个人网站,所有内容不会用来进行牟利,也不会利用任何形式的广告来间接获益,纯粹是为了广大技术爱好者提供技术内容和技术思想的分享性交流网站。

专注分享技术,共同学习,共同进步。侵权联系[81616952@qq.com]

Copyright (C)ICode9.com, All Rights Reserved.

ICode9版权所有