其他分享
首页 > 其他分享> > RAID卡log日志解析

RAID卡log日志解析

作者:互联网


1. During pd spinup
T31: C0:DM_DevSSUCallback  dev 25 Sense Data: Len 12 RespCode 70 senseKey 6 asc 29 ascq 0   <-- Send "Start Stop Unit", received reply "POWER ON, RESET OCCURRED"
T33: C0: Inquiry SU returning Error                                                            <-- Send cmd "Inquriy", not successful since it's spinning up
T33: C0:DM_DevSenseRetry: retry with no Sense                                    <-- Retry this cmd, it's successful
T34: C0: Inquiry VPD86 returning Error                                                     <-- Send cmd "Inquiry VPD886", received reply "INVALID FIELD IN CDB" since drive doesn't support this page
T34: C0:DM_DevSenseRetry  dev 25 Sense Data: Len 12 RespCode 70 senseKey 5 asc 24 ascq 0  <-- Retry this cmd
T34: C0: Inquiry VPD86 returning Error                                                      <-- Failed again
T34: C0:DM_DevSenseRetry  dev 25 Sense Data: Len 12 RespCode 70 senseKey 5 asc 24 ascq 0   <-- Retry this cmd  
T34: C0: Inquiry VPD86 returning Error                                                      <-- Failed again  
T34: C0:DM_DevSenseRetry  dev 25 Sense Data: Len 12 RespCode 70 senseKey 5 asc 24 ascq 0  <-- After 3 times retry, give up and skip to next cmd
 
2. During enclosure initialization
T34: C0:SES_InitEnclosure: Enclosure 23 : enclIdx: 1 Initialization started 
T34: C0:SES_GenericCallback: enclPd=23...RDM_STATUS =1 retries: 0
T34: C0:Cmd Details: 40c64a88 :1c 01 00 00 20 00 
T34: C0:SES General Error on EnclPd:23  sts:1  RetryCount:0  msg:40c64a00  txfrAddr:43897fa0  <-- error happens saying "underrun" since Enclosure is initializing, not ready yet, will retry and it's successful.

标签:DM,RAID,log,Sense,Error,T34,C0,日志,RespCode